Panes bonded to an interlayer, to your make-up

Onos laminates glass in its own factory for installers, glazing firms, main contractors, facade contractors and fit-out companies in Dubai and across the UAE. Two or more panes are bonded to an interlayer that holds the glass together if it breaks. We toughen the panes first where the make-up calls for it, and supply the glass on its own or glazed into our frames.

Laminated glass is chosen when the glass has to stay in place after it breaks: in balustrades, overhead and roof glazing, and facades over public areas. With the right interlayer it also cuts noise, which is why acoustic laminated glass appears in window and partition specifications.

Looking up through a frameless glass roof with point fixings

How laminated glass works

A laminated pane is a sandwich: glass, interlayer, glass, with more layers where the design needs them. The panes are cut and edge-worked first, toughened where specified, then assembled with the interlayer and bonded into one pane. Laminated safety glass is described by ISO 12543-2 and EN 14449; in US specifications, by ASTM C1172.

When a ply breaks, the fragments stay stuck to the interlayer (Kuraray). How much a broken pane can still carry depends on the glass, the interlayer and the supports: if both plies of a fully toughened laminate break, the whole pane may leave the opening (NGA). That is why the project engineer sets the make-up.

  • Annealed laminated: panes laminated without heat treatment
  • Toughened laminated: each ply toughened, and heat-soaked where specified, before laminating
  • Acoustic laminated: an acoustic interlayer for noise reduction
  • Laminated panes as one or both leaves of a double glazed unit

Where laminated glass is used

The specification decides where laminated glass is required. These are the places it most often appears.

Interlayers

The interlayer decides how the pane behaves once it is broken, how stiff it is, and how well it reduces noise. PVB makes up more than 90% of laminated safety glass interlayers (Kuraray). Ionoplast interlayers such as SentryGlas are far stiffer and are named for balustrades, overhead glazing and facades (Kuraray). Acoustic PVB targets the 1,000–4,000 Hz range (Eastman). We laminate with clear and acoustic PVB and with SGP ionoplast; name the interlayer, or the performance it must reach, on the glass schedule.

Exposed edges need thought. On a frameless balustrade the laminated edge stays visible (see our guide to glass balustrade requirements), so the specification should say whether the edges are polished and how they are protected.

Our laminated glass range

Indicative production ranges. Each quotation confirms the make-ups for your project.

ItemRange
Make-ups6.38 to 25.52 mm, annealed or toughened plies
InterlayersPVB 0.38, 0.76 and 1.52 mm; acoustic PVB; SGP
Maximum pane size2,440 × 4,800 mm
GlassClear, low-iron, tinted and coated
PliesTwo or more, heat-soaked where specified
EdgesGround, or polished where the edge is exposed

Make-ups outside these ranges: send the details and we will confirm what we can supply.

Specification and what to send

Send these with a quote request:

  • Pane references that match the drawings and the schedule
  • The make-up per reference: each ply’s thickness and glass type, and the interlayer
  • Which plies are toughened, and which need heat soaking
  • Sizes and quantities, with the edge finish and any holes or notches
  • Acoustic or other performance targets, where the specification sets them
  • Laminated glass only, or made into double glazed units or glazed into our frames
  • The delivery programme

Send your glass schedule

Send the drawings and the laminated glass make-ups. We reply with clarifications or a written quotation, glass only or with frames.

Send drawings. Get a fabrication price.

Tell us what you need. Onos replies with questions or a written fabrication quotation, and never quotes for installation.

  1. Drawings: elevations, sections and the opening or panel schedule
  2. System and series, or the performance the specification asks for
  3. Finish, glass make-up and hardware
  4. Quantities or a BOQ, and the delivery emirate
  5. Programme: when you need fabricated units on site
  6. Who installs: your team or your nominated installer

Drawings and BOQs: [email protected]

We use your details only to reply to your request — see our privacy policy. Drawings or a BOQ can be emailed to [email protected].

Send drawings, a BOQ or quantities for a fabrication quote.

Request a Quote WhatsApp