Onos glazes the aluminium windows, doors, partitions, balustrades and unitised curtain wall panels it fabricates, for installers and contractors across the UAE. The glass comes from our own lines: cut, toughened, laminated or made into insulating units to your approved glass schedule, then glazed into our frames in the factory.
In UAE trade speech this is aluminium and glazing works. Glazing is where our two services meet: our aluminium fabrication makes the frame and our glass fabrication makes the glass. Each pane or unit is checked against the schedule and the system’s glazing range, set on the right blocks and fixed with the system’s gaskets and beads.
Units are glazed in our factory, including the unitised panels in our facade fabrication. Frames can also leave unglazed, and the glass can be ordered on its own. For the glass in glass balustrades, see our guide to glass balustrade requirements.
Aluminium units we glaze
Factory glazing applies to the units we fabricate. Windows and doors can be supplied glazed or unglazed, as agreed in the quotation, and the choice can change from mark to mark.
Unglazed frames travel with the system’s beads and gaskets for the scheduled glass thickness. Unitised panels are the exception: glazing is part of assembling the panel in the factory.
- Aluminium windows: insulated or single-pane make-ups
- Aluminium doors: toughened or laminated glass in leaves and side panels
- Unitised curtain wall panels: assembled and glazed in the factory
- Partitions and balustrades: toughened or laminated glass within the system’s limits
Glass types we glaze
The consultant’s specification sets the make-up. It draws on these glass types, alone or combined in one unit, processed on our own lines before glazing: see toughened, laminated and double glazed units.
-
Toughened (tempered)
Heat-treated safety glass, also called securit or power glass in UAE trade speech. ASTM C1048 covers it alongside heat-strengthened glass, a different product, so name the treatment.
-
Laminated
Panes bonded to an interlayer that holds the fragments in place if the glass breaks.
-
Heat-soaked toughened
Toughened glass heat-soaked to EN 14179-1 to reduce the risk of nickel-sulphide spontaneous breakage. The extra step affects cost and programme.
-
Insulating glass units
Panes sealed around a cavity, covered by the EN 1279 series and specified as a make-up per opening.
-
Solar-control low-E
Coated glass that limits solar heat gain while letting daylight through, specified by shading coefficient, light transmittance and U-value.
Specification and what to send
Write each make-up from outside to inside: outer pane, cavity, inner pane, with the thickness and type of each, any coating and the surface it sits on. One line per make-up, referenced to the openings that use it, gives the glass schedule and the quotation the same starting point.
The consultant or facade engineer sets the make-up and the performance targets; we check that each make-up fits the chosen system. Choose glass and frame together, because a window’s overall U-value counts the frame too: Schüco publishes Uf from 0.9 W/m²K for AWS 75.SI+, Reynaers 1.0 W/m²K for MasterLine 8.
Send these with a quote request:
- Opening references that match the drawings and the window and door schedule
- The make-up per opening, outside to inside, with coatings and their surfaces
- Cavity width, air or argon fill and spacer type, for insulating units to the EN 1279 series
- Glass type by location: toughened, laminated or heat-soaked, as the specification sets it
- Performance targets: U-value, shading coefficient and light transmittance, and ASTM E2190 where the specification cites it
- Sizes and quantities, glazed or unglazed supply, and the delivery programme
Glazing ranges by system
Each system publishes a glazing range, and its beads and gaskets suit the actual make-up thickness. A change after sign-off can change the beads, the gaskets and sometimes the series, so fix the final thickness per opening before fabrication.
| Series | Type | Published glass limit |
|---|---|---|
| Schüco AWS 75.SI+ | Window | Glass up to 61 mm (Schüco UAE) |
| Schüco AF UDC 80 | Unitised facade | Glass up to 70 mm; units up to 3,000 × 4,000 mm (Schüco) |
| Reynaers MasterLine 8 | Window | Glass 13–72 mm (Reynaers) |
| Reynaers HiFinity | Minimal sliding | Glass 36–54 mm (Reynaers) |
| Reynaers ConceptWall 50 | Stick curtain wall | Glass weight up to 700 kg (Reynaers) |
| Inoform F90 Premium | Window | Glazing up to 55 mm (Inoform Systems) |
These are the ranges and maximums each system house publishes for its tested configurations; Reynaers notes that performance depends on the profile combination (Reynaers). See the systems we fabricate for the series behind each package.
Reference images
Glazed aluminium and glass in UAE buildings: atria, towers, facades and interior screens.
Licensed stock photographs, shown for illustration. Not Onos projects.
How we work
Seven stages take a glazed package from your schedule to site. The make-up is settled before any glass is cut.
-
Send the schedule
Drawings, glass schedule, system and finish come to us with the RFQ.
-
Make-up check
Each make-up is checked against the system’s glazing range, the pane weight and the specification. One that does not fit is raised as a clarification.
-
Quotation
Glass is priced per make-up and opening type. Make-up, extra processing, pane size and weight, and the number of make-ups move the price most.
-
Sign-off
You confirm sizes, make-ups and samples before glass is committed.
-
Process the glass
Panes are cut, edge-worked and drilled, then toughened, laminated or made into insulating units on our own lines, in the make-up per opening.
-
Glaze and inspect
Units are glazed with the system’s blocks, gaskets and beads, then checked for make-up against the schedule, orientation of coated faces, edge condition and gasket contact.
-
Label and deliver
Glazed units are labelled to the schedule, protected and delivered in the agreed drops for your team to install.
Send your glass schedule
Send the drawings, the glass schedule and the system choice. We reply with clarifications or a written quotation that prices the glass make-up by make-up.
Explore more
-
Toughened Glass
Cut, edge-worked and drilled, then toughened and heat-soaked
-
Double Glazed Units
Insulating glass units made to the make-up per opening
-
Aluminium Windows
Fabricated to your window schedule, supplied for your installers
-
Unitised Curtain Wall
Facade panels assembled in our factory, supply only
Send drawings. Get a fabrication price.
Tell us what you need. Onos replies with questions or a written fabrication quotation, and never quotes for installation.
- Drawings: elevations, sections and the opening or panel schedule
- System and series, or the performance the specification asks for
- Finish, glass make-up and hardware
- Quantities or a BOQ, and the delivery emirate
- Programme: when you need fabricated units on site
- Who installs: your team or your nominated installer
Drawings and BOQs: [email protected]